C00614 | resp. to can life guarding error, C00615 | resp. to imp. device config, C00618 | no. of crc cycles – Lenze 9400 User Manual

Page 805: C00614, C00613/1, C00615/2, C00615/3, 14 parameter reference

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

805

14

Parameter reference

14.2

Parameter list | C00614

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00614

C00615

C00618

Parameter | Name:

C00614 | Resp. to CAN life guarding error

Data type: UNSIGNED_8

Index: 23961

d

= 5D99

h

Response of slave if node guarding request is not received.

"CAN on board" system bus: node guarding protocol

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00615 | Resp. to imp. device config.

Data type: UNSIGNED_32

Index: 23960

d

= 5D98

h

Selection list

1 Fault
3 Quick stop by trouble
4 Warning locked
6 Information
0 No response

Subcodes

Lenze setting

Info

C00615/1

0: No response

Reserved

C00615/2

1: Fault

Resp. to imp. module in MXI1

C00615/3

1: Fault

Resp. to imp. module in MXI2

C00615/4

0: No response

Reserved

C00615/5

0: No response

Reserved

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00618 | No. of CRC cycles

Data type: UNSIGNED_32

Index: 23957

d

= 5D95

h

Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1