Parameter reference

14.2

Parameter list | C00640

808

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00640

C00641

C00642

C00643

Parameter | Name:

C00640 | Resp. to pole pos. id. monit.

Data type: UNSIGNED_32

Index: 23935

d

= 5D7F

h

From software version V4.0

Error response for abort of the

pole position identification

Adjustment of the pole position identification

Selection list

(Lenze setting printed in bold)

1 Fault
4 Warning locked
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00641 | PLI 360° current amplitude

Data type: UNSIGNED_32

Index: 23934

d

= 5D7E

h

From software version V4.0

Percentage adjustment of the current amplitude for the

pole position identification

Stop!

If there is no temperature monitoring in the motor and/or the I2xt motor monitoring is not parameterised correctly,

the motor may be permanently damaged when the current amplitude is set too high (e.g. to the maximum value)!

Adjustment of the pole position identification

Setting range

(min. value | unit | max. value)

Lenze setting

1

%

1000 100 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00642 | PolePosId 360° ramp time

Data type: UNSIGNED_32

Index: 23933

d

= 5D7D

h

From software version V4.0

Percentage adjustment of the ramp time for the

pole position identification

Adjustment of the pole position identification

Setting range

(min. value | unit | max. value)

Lenze setting

5

%

1000 100 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00643 | PLI 360° traversing direction

Data type: UNSIGNED_32

Index: 23932

d

= 5D7C

h

From software version V4.0

Selection of the traversing direction for the

pole position identification

Adjustment of the pole position identification

Selection list

(Lenze setting printed in bold)

0 Right rotating field
1 Left rotating field

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1