C00644 | poleposid 360˚ fault tol, C00645 | pli 360˚ absolute current amplitude, C00646 | pli min.mov. curr. amplitude – Lenze 9400 User Manual

Page 809: C00647 | poleposid min.mov. cur.rise rate, C00646, C00644, C00647, 14 parameter reference

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

809

14

Parameter reference

14.2

Parameter list | C00644

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00644

C00645

C00646

C00647

Parameter | Name:

C00644 | PolePosId 360° fault tol.

Data type: INTEGER_32

Index: 23931

d

= 5D7B

h

From software version V4.0

Fault tolerance for the plausibility check of the

pole position identification

Adjustment of the pole position identification

Setting range

(min. value | unit | max. value)

Lenze setting

-6.0

°

30.0 0.0 °

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00645 | PLI 360° absolute current amplitude

Data type: UNSIGNED_32

Index: 23930

d

= 5D7A

h

From software version V7.0

Adjustment of the pole position identification

Display range

(min. value | unit | max. value)

0.00

A

1000.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00646 | PLI min.mov. curr. amplitude

Data type: UNSIGNED_32

Index: 23929

d

= 5D79

h

From software version V4.0

Percentage adjustment of the current amplitude for the

pole position identification

Stop!

If there is no temperature monitoring in the motor and/or the I2xt motor monitoring is not parameterised correctly,

the motor may be permanently damaged when the current amplitude is set too high (e.g. to the maximum value)!

Adjustment of the pole position identification

Setting range

(min. value | unit | max. value)

Lenze setting

1

%

1000 100 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00647 | PolePosId min.mov. cur.rise rate

Data type: UNSIGNED_32

Index: 23928

d

= 5D78

h

From software version V4.0

Percentage adjustment of the rate of current rise for the

pole position identification

Adjustment of the pole position identification

Setting range

(min. value | unit | max. value)

Lenze setting

5

%

1000 100 %

Read access  Write access  CINH  PLC STOP  No transfer