C00812 | mctrl_dnmotorposrefvalue, C00813 | mctrl_dnloadposrefvalue, C00814 | mctrl_dnboost – Lenze 9400 User Manual

Page 820: C00815 | mctrl_dnspeedctrlintegrator, C00816 | mctrl_dnfieldweak, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00812

820

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00812

C00813

C00814

C00815

C00816

Parameter | Name:

C00812 | MCTRL_dnMotorPosRefValue

Data type: UNSIGNED_32

Index: 23763

d

= 5CD3

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

0

Incr.

4294967295

Subcodes

Info

C00812/1

LOW word

C00812/2

High word

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00813 | MCTRL_dnLoadPosRefValue

Data type: UNSIGNED_32

Index: 23762

d

= 5CD2

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

0

Incr.

4294967295

Subcodes

Info

C00813/1

LOW word

C00813/2

High word

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00814 | MCTRL_dnBoost

Data type: INTEGER_32

Index: 23761

d

= 5CD1

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-1000

V

1000

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00815 | MCTRL_dnSpeedCtrlIntegrator

Data type: INTEGER_32

Index: 23760

d

= 5CD0

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-2147483.647

Nm

2147483.647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C00816 | MCTRL_dnFieldWeak

Data type: INTEGER_32

Index: 23759

d

= 5CCF

h

Internal motor control (MCTRL) signal
Display range

(min. value | unit | max. value)

-200.00

%

200.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Advertising