Parameter reference

14.2

Parameter list | C00909

822

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00909

C00950

C00951

Parameter | Name:

C00909 | Speed limitation

Data type: INTEGER_16

Index: 23666

d

= 5C72

h

Speed limitation for speed setpoint

• For the upper speed limit value only positive values are permissible (0.0 % ... 175.0 %).

• For the lower speed limit value only negative values are permissible (-175.0 % ... 0.0 %).

Setting range

(min. value | unit | max. value)

-175.0

%

175.0

Subcodes

Lenze setting

Info

C00909/1

175.0 %

Upper speed limit value

C00909/2

-175.0 %

Lower speed limit value

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00950 | VFC: V/f characteristic shape

Data type: UNSIGNED_32

Index: 23625

d

= 5C49

h

From software version V3.0

V/f control

Selection list

(Lenze setting printed in bold)

0 Linear (V/f)
1 Quadratic (V/f²)
2 Curve

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00951 | VFC: V/f base frequency

Data type: INTEGER_32

Index: 23624

d

= 5C48

h

From software version V3.0

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

1

Hz

5000 50 Hz

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1