Parameter reference

14.2

Parameter list | C00963

826

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00963

C00964

C00965

C00966

C00967

Parameter | Name:

C00963 | VFC: Gain - Imax controller

Data type: UNSIGNED_32

Index: 23612

d

= 5C3C

h

From software version V3.0

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

Hz/A

1000.000 0.001 Hz/A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C00964 | VFC: Reset time - Imax contr.

Data type: UNSIGNED_32

Index: 23611

d

= 5C3B

h

From software version V3.0

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

2000.0 100.0 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00965 | VFC: Gain - slip compensation

Data type: INTEGER_32

Index: 23610

d

= 5C3A

h

From software version V3.0

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

-200.00

%

200.00 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00966 | VFC: Time const. slip comp.

Data type: UNSIGNED_32

Index: 23609

d

= 5C39

h

From software version V3.0

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

1

ms

6000 2000 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00967 | VFC: Gain - oscillation damping

Data type: INTEGER_32

Index: 23608

d

= 5C38

h

From software version V3.0

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

-100

%

100 20 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1