14.2

Parameter list | C01195

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01195

C01196

C01197

C01198

Parameter | Name:

C01195 | Influence winding I²xt mon.

Data type: UNSIGNED_32

Index: 23380

d

= 5B54

h

I

2

xt motor monitoring: Influence of the winding temperature

• By setting "0 %", the time constant for the winding is not considered and the thermal model is only calculated

with the time constant set for the housing/laminated core.

I2xt motor monitoring

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 0 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C01196 | S1 torque characteristic I²xt mon.

Data type: UNSIGNED_32

Index: 23379

d

= 5B53

h

• By selecting a characteristic, the permissible motor current is evaluated depending on speed for calculating the

thermal motor utilisation.

I2xt motor monitoring

Setting range

(min. value | unit | max. value)

0

%

600

Subcodes

Lenze setting

Info

C01196/1

0 %

S1 torque characteristic n1/nn

C01196/2

100 %

S1 torque characteristic I1/In

C01196/3

0 %

S1 torque characteristic n2/nn

C01196/4

100 %

S1 torque characteristic I2/In

C01196/5

100 %

S1 torque characteristic n3/nn

C01196/6

100 %

S1 torque characteristic I3/In

C01196/7

100 %

S1 torque characteristic n4/nn

C01196/8

100 %

S1 torque characteristic I4/In

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C01197 | Starting value I²xt monitoring

Data type: UNSIGNED_32

Index: 23378

d

= 5B52

h

From software version V11.0

I2xt motor monitoring

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

200 0 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C01198 | Async. motor: Stall protection

Data type: UNSIGNED_32

Index: 23377

d

= 5B51

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 0 %