C01210 | counter: internal, C01212 | counter: power section overload, C01214 | internal clock – Lenze 9400 User Manual

Page 840: 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C01210

840

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01210

C01211

C01212

C01213

C01214

Parameter | Name:

C01210 | Counter: Internal

Data type: UNSIGNED_8

Index: 23365

d

= 5B45

h

From software version V8.0

Display range

(min. value | unit | max. value)

0

255

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C01211 | Service code

Data type: UNSIGNED_32

Index: 23364

d

= 5B44

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C01212 | Counter: Power section overload

Data type: UNSIGNED_16

Index: 23363

d

= 5B43

h

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C01213 | Service code DataFlash

Data type: UNSIGNED_32

Index: 23362

d

= 5B42

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C01214 | Internal clock

Data type: VISIBLE_STRING

Index: 23361

d

= 5B41

h

Display of the system time of the controller in the format "dd/mm/yyyy hh:mm:ss"

• Time and date are set via

C01215

.

If the MM440 memory module with real-time clock is plugged into the controller, the internal clock is adjusted to

the real-time clock every time the mains is switched on and every 24 hours at 0:00 o'clock.

• The daily adjustment is executed on a low-priority level. This is why it may take some seconds until the adjusted

time is displayed.

• During the adjustment process, status information of the real-time clock is also queried and entered into the

logbook.

Note:

If a memory module without real-time clock is plugged into the controller, the internal clock is initialised with

"01.01.1970 00:00:00" every time the mains is switched on.

Read access  Write access  CINH  PLC-STOP  No transfer

Scaling factor: 1

Character length: 21