C01705 | energy: power input, C01902 | diagnostics x6: max. baud rate, C01903 | diagnostics x6: change baud rate – Lenze 9400 User Manual

Page 846: C01905 | diagnostics x6: curr. baud rate, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C01705

846

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01705

C01902

C01903

C01905

Parameter | Name:

C01705 | Energy: Power input

Data type: UNSIGNED_32

Index: 22870

d

= 5956

h

From software version V9.0

Setting range

(min. value | unit | max. value)

0

W

4294967295

Subcodes

Lenze setting

Info

C01705/1

0 W

Energy m. 1: Power input

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C01902 | Diagnostics X6: Max. baud rate

Data type: UNSIGNED_32

Index: 22673

d

= 5891

h

Maximum permissible baud rate of the standard device after determination of the baud rate at the diagnostic

interface X6

• Communication starts with the default standard device baud rate of 19200 baud.

Selection list

(Lenze setting printed in bold)

9600 9600 baud

19200 19.200 baud
38400 38.400 baud
57600 57.600 baud

115200 115.200 baud
230400 230.400 baud
375000 375.000 baud
750000 750.000 baud

1500000 1.500.000 baud
3000000 3.000.000 baud

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C01903 | Diagnostics X6: Change baud rate

Data type: UNSIGNED_32

Index: 22672

d

= 5890

h

New determination of the baud rate at the diagnostic interface X6
Selection list

(Lenze setting printed in bold)

1 Set a higher baud rate
0 Ignore changes

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C01905 | Diagnostics X6: Curr. baud rate

Data type: UNSIGNED_32

Index: 22670

d

= 588E

h

Current baud rate at diagnostics interface X6
Display range

(min. value | unit | max. value)

0

3000000

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising
This manual is related to the following products: