14

Parameter reference

14.2

Parameter list | C02556

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02556

C02557

C02558

C02559

C02560

Parameter | Name:

C02556 | Pos. contr. limitation

Data type: INTEGER_32

Index: 22019

d

= 5603

h

Motor interface

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s

214748.3647 214748.3647 Unit/s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02557 | Phase controller output

Data type: INTEGER_32

Index: 22018

d

= 5602

h

Motor interface

Display range

(min. value | unit | max. value)

-214748.3647

Unit/s

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02558 | Pos. contr. output

Data type: INTEGER_32

Index: 22017

d

= 5601

h

Motor interface

Display range

(min. value | unit | max. value)

-214748.3647

Unit/s

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02559 | Internal torque limits

Data type: INTEGER_32

Index: 22016

d

= 5600

h

Motor interface

Display range

(min. value | unit | max. value)

-200.00

%

200.00

Subcodes

Info

C02559/1

Upper int. torque limit

C02559/2

Lower int. torque limit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C02560 | Messages - motor interface

Data type: UNSIGNED_32

Index: 22015

d

= 55FF

h

Motor interface

Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1