C02575 | actual position (enc. eval.), C02576 | following error, C02577 | external actual position – Lenze 9400 User Manual

Page 861: C02578 | offset actual pos. value/setp, C02579 | encoder eval.: dig. signals, C02579/1, C02579/2, C02579/3, C02575, C02576

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

861

14

Parameter reference

14.2

Parameter list | C02575

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02575

C02576

C02577

C02578

C02579

Parameter | Name:

C02575 | Actual position (enc. eval.)

Data type: INTEGER_32

Index: 22000

d

= 55F0

h

Encoder evaluation

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02576 | Following error

Data type: INTEGER_32

Index: 21999

d

= 55EF

h

Encoder evaluation

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02577 | External actual position

Data type: INTEGER_32

Index: 21998

d

= 55EE

h

Encoder evaluation

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02578 | Offset actual pos. value/setp.

Data type: INTEGER_32

Index: 21997

d

= 55ED

h

Encoder evaluation

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02579 | Encoder eval.: Dig. signals

Data type: UNSIGNED_32

Index: 21996

d

= 55EC

h

Display of the digital signals of the

encoder evaluation

.

Selection list

(read only)

0 FALSE
1 TRUE

Subcodes

Info

C02579/1

FDB_bResolverError

C02579/2

FDB_bSinCosSignalError

C02579/3

FDB_bEncoderComError

C02579/4

FDB_bResetPosFollowingError

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1