C02580 | operating mode brake, C02581 | threshold - brake activation, C02582 | brake resp. to pulse inhibit – Lenze 9400 User Manual

Page 862: C02583 | status input monitoring, C02580, Dc-in, C02581, C02580, selection 1, C02580, selection 11, Put by setting

Advertising
background image

14

Parameter reference

14.2

Parameter list | C02580

862

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02580

C02581

C02582

C02583

Parameter | Name:

C02580 | Operating mode brake

Data type: UNSIGNED_32

Index: 21995

d

= 55EB

h

Basic function "

Brake control

"

Selection list

(Lenze setting printed in bold)

0 Brake control off
1 Directly with brake module
2 Autom. with brake module

11 Directly - external switching
12 Autom. - external switching
22 Autom. - DC brake

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02581 | Threshold - brake activation

Data type: INTEGER_32

Index: 21994

d

= 55EA

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

50000 50 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02582 | Brake resp. to pulse inhibit

Data type: UNSIGNED_32

Index: 21993

d

= 55E9

h

Basic function "

Brake control

"

Selection list

(Lenze setting printed in bold)

0 Activate the brake immediately
1 Activate the brake at n < nmin

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02583 | Status input monitoring

Data type: UNSIGNED_32

Index: 21992

d

= 55E8

h

Basic function "

Brake control

"

Selection list

(Lenze setting printed in bold)

0 Not active
1 Active

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising