C02590 | brake opening time, C02591 | waiting time - state monitoring, C02593 | waiting time - brake activation – Lenze 9400 User Manual

Page 864: C02594 | test torque, C02595 | permissible angle of rotation, C02590, C02591, C02593, C02594, C02595

Advertising
background image

14

Parameter reference

14.2

Parameter list | C02590

864

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02590

C02591

C02593

C02594

C02595

Parameter | Name:

C02590 | Brake opening time

Data type: UNSIGNED_32

Index: 21985

d

= 55E1

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

60000 100 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02591 | Waiting time - state monitoring

Data type: UNSIGNED_32

Index: 21984

d

= 55E0

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

60000 100 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02593 | Waiting time - brake activation

Data type: UNSIGNED_32

Index: 21982

d

= 55DE

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

1000.000 0.000 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C02594 | Test torque

Data type: INTEGER_32

Index: 21981

d

= 55DD

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

-21474836.47

Nm

21474836.47 0.00 Nm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C02595 | Permissible angle of rotation

Data type: INTEGER_32

Index: 21980

d

= 55DC

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

°

36000 5 °

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising