C02596 | grinding speed, C02597 | accel./decel. time - grinding, C02598 | grinding on time – Lenze 9400 User Manual

Page 865: C02599 | grinding off time, C02600 | acceleration time feedf. control, C02596, C02597, C02598, C02599, C02600

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

865

14

Parameter reference

14.2

Parameter list | C02596

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02596

C02597

C02598

C02599

C02600

Parameter | Name:

C02596 | Grinding speed

Data type: INTEGER_32

Index: 21979

d

= 55DB

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

300 100 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02597 | Accel./decel. time - grinding

Data type: UNSIGNED_32

Index: 21978

d

= 55DA

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

60.000 1.000 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C02598 | Grinding ON time

Data type: UNSIGNED_32

Index: 21977

d

= 55D9

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.2

s

2.0 0.5 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C02599 | Grinding OFF time

Data type: UNSIGNED_32

Index: 21976

d

= 55D8

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.2

s

2.0 0.5 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C02600 | Acceleration time feedf. control

Data type: UNSIGNED_32

Index: 21975

d

= 55D7

h

From software version V3.0

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

1000.000 0.000 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Advertising