C02601 | ref. for accel. time of brake, C02602 | source for feedf. control brake, C02603 | threshold 1 for opening brake – Lenze 9400 User Manual

Page 866: C02604 | threshold 2 for opening brake, C02601, C02602, C02603, C02604, And select the reference, And set the selection

Advertising
background image

14

Parameter reference

14.2

Parameter list | C02601

866

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02601

C02602

C02603

C02604

Parameter | Name:

C02601 | Ref. for Accel. time of brake

Data type: UNSIGNED_32

Index: 21974

d

= 55D6

h

From software version V3.0

Basic function "

Brake control

"

Selection list

(Lenze setting printed in bold)

0 Motor reference value
1 Current starting value

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02602 | Source for feedf. control brake

Data type: UNSIGNED_32

Index: 21973

d

= 55D5

h

From software version V3.0

Basic function "

Brake control

"

Selection list

(Lenze setting printed in bold)

0 Torque
1 Speed

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02603 | Threshold 1 for opening brake

Data type: INTEGER_32

Index: 21972

d

= 55D4

h

From software version V3.0

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

-50000

rpm

50000 0 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02604 | Threshold 2 for opening brake

Data type: INTEGER_32

Index: 21971

d

= 55D3

h

From software version V3.0

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

-50000

rpm

50000 0 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising