Parameter reference

14.2

Parameter list | C02670

878

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02670

C02671

C02672

C02673

Parameter | Name:

C02670 | Tolerance for POS_bActPosInTarget

Data type: INTEGER_32

Index: 21905

d

= 5591

h

From software version V1.5

Tolerance window for actual value-based evaluation "Target position reached"

(Output POS_bActPosInTarget)

Basic function "

Positioning

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit

214748.3647 0.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02671 | Tolerance for POS_bDriveInTarget

Data type: INTEGER_32

Index: 21904

d

= 5590

h

From software version V5.0

Tolerance window for actual value and setpoint-based evaluation "Drive in the target"

(Output POS_bDriveInTarget)

Basic function "

Positioning

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0001

Unit

214748.3647 2.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02672 | Hysteresis for POS_bDriveInTarget

Data type: INTEGER_32

Index: 21903

d

= 558F

h

From software version V5.0

Hysteresis window for actual value and setpoint-based evaluation "Drive in the target"

(Output POS_bDriveInTarget)

Basic function "

Positioning

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit

214748.3647 1.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02673 | Activate DriveInTarget Modulo

Data type: UNSIGNED_32

Index: 21902

d

= 558E

h

From software version V5.0

For actual value and setpoint-based evaluation "Drive in target" (output POS_bDriveInTarget):

Definition how the modulo evaluation is to be carried out if the actual position value enters the tolerance and

hysteresis window again.

Basic function "

Positioning

"

Selection list

(Lenze setting printed in bold)

0 Only setpoint Cycle
1 All cycles

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1