897

14

Parameter reference

14.2

Parameter list | C02802

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02802

Parameter | Name:

C02802 | Status word: Digital outputs

Data type: BITFIELD_32

Index: 21773

d

= 550D

h

Display of the hexadecimal value of the digital outputs

• Important: All digital levels are indicated without considering the level logic. Internal signals are displayed as

well.

Display area
0x00000000

0xFFFFFFFF

Value is bit-coded:

Bit 0 Reserved
Bit 1 Reserved
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved

Bit 10 Reserved
Bit 11 Reserved
Bit 12 Dig. output. 1: Terminal state
Bit 13 Dig. output. 2: Terminal state
Bit 14 Dig. output. 3: Terminal state
Bit 15 Dig. output. 4: Terminal state
Bit 16 Reserved
Bit 17 Reserved
Bit 18 Reserved
Bit 19 Reserved
Bit 20 Reserved
Bit 21 Reserved
Bit 22 Reserved
Bit 23 Reserved
Bit 24 Reserved
Bit 25 Reserved
Bit 26 Reserved
Bit 27 Reserved
Bit 28 Reserved
Bit 29 Reserved
Bit 30 Reserved
Bit 31 Reserved

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1