C02912 | product count, C02919 | number of cam tracks, C02920 | cam track choice – Lenze 9400 User Manual

Page 907: C02921 | cam track type, C02922 | number of cam data points, C02912, C02919, C02920, C02921, C02922

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

907

14

Parameter reference

14.2

Parameter list | C02912

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02912

C02919

C02920

C02921

C02922

Parameter | Name:

C02912 | Product Count

Data type: UNSIGNED_32

Index: 21663

d

= 549F

h

From software version V3.0

Changing cam data via parameterisation

Display range

(min. value | unit | max. value)

0

65536

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02919 | Number Of Cam Tracks

Data type: UNSIGNED_32

Index: 21656

d

= 5498

h

From software version V3.0

Changing cam data via parameterisation

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02920 | Cam Track Choice

Data type: UNSIGNED_32

Index: 21655

d

= 5497

h

From software version V3.0

Changing cam data via parameterisation

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02921 | Cam Track Type

Data type: UNSIGNED_32

Index: 21654

d

= 5496

h

From software version V3.0

Changing cam data via parameterisation

Selection list

(read only)

1 Linear
5 Spline

11 LinearPC
15 SplinePC

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02922 | Number Of Cam Data Points

Data type: UNSIGNED_32

Index: 21653

d

= 5495

h

From software version V3.0

Changing cam data via parameterisation

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1