C02960 | pos track choice, C02962 | number of pos data points, C02963 | pos data point choice – Lenze 9400 User Manual

Page 911: C02964 | change pos data point x, C02965 | change pos data point y, C02960, C02962, C02963, C02964, C02965

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

911

14

Parameter reference

14.2

Parameter list | C02960

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02960

C02962

C02963

C02964

C02965

Parameter | Name:

C02960 | Pos Track Choice

Data type: UNSIGNED_32

Index: 21615

d

= 546F

h

From software version V3.0

Changing cam data via parameterisation

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02962 | Number of Pos Data Points

Data type: UNSIGNED_32

Index: 21613

d

= 546D

h

From software version V3.0

Changing cam data via parameterisation

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02963 | Pos Data Point Choice

Data type: UNSIGNED_32

Index: 21612

d

= 546C

h

From software version V3.0

Changing cam data via parameterisation

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02964 | Change Pos Data Point X

Data type: INTEGER_32

Index: 21611

d

= 546B

h

From software version V3.0

Changing cam data via parameterisation

Setting range

(min. value | unit | max. value)

Lenze setting

-214748.3647

Unit

214748.3647 0.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02965 | Change Pos Data Point Y

Data type: INTEGER_32

Index: 21610

d

= 546A

h

From software version V3.0

Changing cam data via parameterisation

Setting range

(min. value | unit | max. value)

Lenze setting

-214748.3647

Unit

214748.3647 0.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Advertising
This manual is related to the following products: