A1, a2, and com–analog outputs, A1, a2, and com – analog outputs, Analog 1 and analog 2 output circuits – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 108: Analog outputs analog 1 and analog 2, E 6-44

Advertising
background image

Publication 1398-5.0 – October 1998

6-44

Interfaces

6Interfaces

A1, A2, and COM – Analog
Outputs

Analog outputs may be monitored with external equipment, such as an
oscilloscope, on the external output pins A1 (ANALOG 1), A2
(ANALOG 2) and COM (COMMON). These output signals are
parallel connections to the analog command signals available on
connector J1. Refer to “Analog Outputs” on page 6-16.

A 12-bit digital-to-analog converter (DAC) generates ANALOG 1.
ANALOG 2 is a filtered PWM signal with 8 bit resolution and a
carrier frequency of 32.8 kHz. Both outputs are scaled to a range of
-10 to +10 Volts.

Table 6.16 on page 6-17 lists the output specifications for the signals.

Figure 6.43

ANALOG 1 and ANALOG 2 Output Circuits

Intro

Drive

A1 or A2

-5 VDC

10K

100

-

+

20K

ANALOG
OUTPUT

Table 6.26:

Analog outputs ANALOG 1 and ANALOG 2

Analog Output

Pin

Number

Description

Pin

Number

ANALOG 1

A1

Selectable analog output with 12 bit resolution.
Displays any firmware variable with selectable
scale and offset.

J1-30

ANALOG 2

A2

Selectable analog output with 8 bit resolution.
Displays any firmware variable with selectable
scale and offset.

J1-31

COMMON

COM

Analog Common return.

J1-28

Advertising