Publication 1398-5.0 – October 1998

Application and Configuration Examples

8-41

Configuration

Carefully check all connections before entering these parameters.

1. Switch the AC Power to ON and verify:

• green DC BUS LED is ON

• display shows an operational status: A, F or P (Analog, Fol-

lower or Preset mode of operation). Refer to “Operating Mes-
sages” on page 10-1 f
or an explanation of the display codes.

2. Start ULTRA Master on the PC.

3. Choose

Cancel

from the Drive Select dialog box.

4. Select

P

C Set Up

from the Communications menu in

ULTRA Master to display the personal computer’s communica-
tion settings.

5. Verify the communications port settings of the PC match those of

the drive.

• If the settings are correct, select

OK

in the Port – Settings dia-

log box.

• If the settings are different, correct the Port – Settings to allow

communications with the drive.

Factory default communications Port – Settings for the drive
are:

– Baud Rate:

9600

– Data Bits:

8

– Parity:

None

– Stop Bits:

1

– Serial Port:

COM1

Refer to the section “RS-232 Communication Test” on page 11-11
for troubleshooting instructions.

6. Select

Read Drive

P

arameters

from the Communications menu.

7. Verify the Drive Name and Address are correct for the drive that

is being addressed.

8. Choose

OK

to load the drive parameters.

Note: A motor must be selected for the parameters to load.