Publication 1398-5.0 – October 1998

Application and Configuration Examples

8-13

Connection Diagram

Configuration

Carefully check all connections before entering these parameters.

1. Switch the AC Power to ON and verify:

• green DC BUS LED is ON

• display shows an operational status: A, F or P (Analog, Fol-

lower or Preset mode of operation). Refer to “Operating Mes-
sages” on page 10-1 f
or an explanation of the display codes.

2. Start ULTRA Master on the PC.

3. Choose

Cancel

from the Drive Select dialog box.

4. Select

P

C Set Up

from the Communications menu in

ULTRA Master to display the personal computer’s communica-
tion settings.

Figure 8.3

Master Encoder Connection Diagram

Intro

J1

1 +5V

1

2 5V COM

14 AX+

15 AX-

16 BX+

Close to ENABLE Drive

Close to RESET Fault

17 BX-

Close to Turn ON

18 IX+

19 IX-

20 ENABLE

21 FAULT

26 +24V

32 INPUT1

Master

Encoder

Note 1.

Refer to Figure 6.23, 6.24, 6.25, 6.26, 6.27, 6.28 and 6.29 for additional details

on the Control Interface Cable.

J4

DRIVE

TB1

2 RCV

3 XMT

5 COM

L1

L2/N

Gnd

XMT

RCV

COM

L1

L2/N

Gnd

100-240 VAC

50/60 Hz

Three Phase

Power Source

L3

or

100-240 VAC

50/60 Hz

Single Phase

Power Source

TB1

RESET

TB1

Phase R 1

Phase S 2

Phase T 3

Motor Gnd 4

J2

Motor
Encoder