F- or h-series motors to ultra 200 series drive, F or h-series motor – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 239

Advertising
background image

Publication 1398-5.0 – October 1998

Cable Diagrams, Schematics and Examples

B-27

Figure B.27

F- or H-Series Motors to ULTRA 200 Series Drive
using P2 Terminal Strip

Intro

NOTES:

This wiring method provides the option to run cables through a restrictive bulkhead or enclosure.

Cable 9101-1365-XXX has a connectors on the motor end only. The cable connector is molded
and potted to the cable and may not be disassembled. Refer to the schematic for cable 9101-
1366-XXX for information on wiring this cable to the J2 Terminal Strip.

Adaptor Kit 9101-1391 includes the 3 foot cable, screw terminal strip and mounting bracket. The
cable has a 50-pin Mini D ribbon connector at the drive end and a 50-pin D connector at the termi-
nal strip end.

Adaptor Kit 9101-1392 includes the 3 foot cable, screw terminal strip and mounting bracket. The
cable has a 20-pin Mini D Ribbon connector at the drive end and a 20-pin D connector at the ter-
minal strip end.

Motor Power Cables - Use ULTRA 200 Series cables if the CE Mark is required. Other cables may
be used if the CE Mark is not an issue. In either case, the shield on the motor power cable must be
properly grounded at both ends; the shield is grounded at the motor end when the MS connector is
mated.

Motor Power Cable

Clamp exposed

to the chassis

F or H-Series Motor

Motor Power Connector

Encoder Connector

P2

9

101

-1

365

-X

XX

ground terminal

motor cable shield

Screw Terminal Strip

Enclosure/Cabinet

P1

9101-1391

To

Control

Interface

9101-1392

Screw Terminal Strip

Advertising