J2 – Encoder

J2 is a 20 pin female mini-D ribbon connector (AMP 2-178238-2). It
connects the motor encoder, hall effect switches, and the thermostat to
the ULTRA 200 Series drive. Contact between the connector shell and
a grounded chassis provides shield termination.

Allen-Bradley cables are available in various lengths for connecting
between J2 and an encoder. “Options and Accessories” on page A-1
lists the cables that are available. “J2 Terminal Strip/Breakout Board”
on page 6-30
details the optional signal extension kit.

Pin Signal

Description

Pin Signal

Description

1 EPWR

Encoder
Power

11 I (+)

Motor Encoder
Input
Channel I(+)

2 ECOM

Encoder
Common

12 I (-)

Motor Encoder
Input
Channel I(-)

3 EPWR

Encoder
Power

13 HALL A

Hall Effect A

4 ECOM

Encoder
Common

14 HALL B

Hall Effect B

5 SENSE

(+)

Encoder
Power
Sense (+)

15 HALL C

Hall Effect C

6 SENSE

(-)

Encoder
Power
Sense (-)

16 ABS

Absolute
Position

7 A (+)

Motor Encoder
Input
Channel A(+)

17

Reserved

8 A (-)

Motor Encoder
Input
Channel A(-)

18

Reserved

9 B (+)

Motor Encoder
Input
Channel B(+)

19 TS(+)

Thermal
Switch (+)

10 B (-)

Motor Encoder
Input
Channel B(-)

20 TS(-)

Thermal
Switch (-)

pin 10

pin 11

pin 20

pin 1

!

Intro

ATTENTION: Ensure that the encoder signals are con-
nected as shown in Figure 6.36. Incorrect connection of the
encoder signals will result in improper rotor position, incor-
rect commutation and/or a runaway motor condition.