Creating Custom Motor Files

D-3

The text string translates the table ID into a real motor model number
for display. For example, the user can select the text string “H-4030-P-
H” rather than entering the table ID #23. Figure D.1 defines the text
string format of Allen-Bradley motors.

Motor Phasing

The phasing of the back-EMF and Hall feedback signals must be
verified before a custom motor file can be created. Allen-Bradley
motors use back-EMF and Hall feedback signals phased as shown in
Figure D.2. Motors not manufactured by Allen-Bradley require the
back-EMF and Hall feedback signals be phased to match those of
Allen-Bradley motors. Often this requires swapping of the R- and T-
phase control signals with each other, as well as swapping the Hall A,
Hall B, and Hall C signals with each other.

Back-EMF and Hall Signals

Figure D.2(a) shows the required phasing of the line-to-line back-
EMF signals and Figure D.2(b) shows the proper phasing of the Hall
feedback signals, when the motor is rotating clockwise (CW) as seen
looking at the motor shaft from the load
.

The relationship of the Hall signals to the back-EMF signals is not
important at this stage. However, the sequencing of the back-EMF
signals must conform to Figure D.2(a), and the sequencing of the Hall
feedback signals must conform to Figure D.2(b).

Figure D.1

Allen-Bradley Motor Naming Convention

Intro

Motor Part Number

H - 4030 - P - H - 00 - AA

MOTOR WINDING K DESIGNATOR

E

SERIES DESIGNATOR

E = COMMERCIAL
F = MEDIUM INERTIA
H = LOW INERTIA

I = INDUCTION

LD = LIGHT INDUSTRIAL
N = NEMA STYLE FRAME
W = WASHDOWN
Y = LIGHT INDUSTRIAL

FRAME SIZE

FACTORY DESIGNATED SPECIAL OPTIONS

00
01
02

=
=
=

STANDARD
90 VDC BRAKE
24 VDC BRAKE

OPTICAL ENCODER LINECOUNT

F
H
J
K
L
M
N

=
=
=
=
=
=
=

1000
2000 (STANDARD)
2500
5000

500

3000
1000

FACTORY DESIGNATED SPECIAL OPTIONS

AA
AF
AG
AN

=
=
=
=

STANDARD
FLYING LEADS
IEC DIMENSIONS
NEMA 56C

FACTORY DESIGNATED SPECIAL OPTIONS

AA

= STANDARD

AF

= FLYING LEADS

AG

= IEC DIMENSIONS

AN

= NEMA 56C

FACTORY DESIGNATED SPECIAL OPTIONS

00

= STANDARD

01

= 90 VDC BRAKE

02

= 24 VDC BRAKE

OPTICAL ENCODER LINECOUNT

F

= 1000

H

= 2000 (STANDARD)

J

= 2500

K

= 5000

L

=

500

M

= 3000

N

= 1000

MOTOR WINDING K

E

DESIGNATOR

FRAME SIZE

SERIES DESIGNATOR

E

= COMMERCIAL

F

= MEDIUM INERTIA

H

= LOW INERTIA

I

= INDUCTION

N

= NEMA STYLE FRAME

W

= WASHDOWN

Y

= LIGHT INDUSTRIAL