Connection diagram, Configuration, Step/direction controller connection diagram – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 142

Advertising
background image

Publication 1398-5.0 – October 1998

8-18

Application and Configuration Examples

6. Connect the drive to a 100/240 VDC, 50/60 Hz power source

appropriate to the drive:

• Single Phase: 1398-DDM-010, 1398-DDM-010X,

1398-DDM-020, 1398-DDM-020X, 1398-DDM-030,
1398-DDM-030X, 1398-DDM-075 or 1398-DDM-075X

• Three Phase: 1398-DDM-075, 1398-DDM-075X,

1398-DDM-150 or 1398-DDM-150X

Connection Diagram

Configuration

Carefully check all connections before entering these parameters.

1. Switch the AC Power to ON and verify:

• green DC BUS LED is ON

• seven segment display shows an operational status: A, F or P

(Analog, Follower or Preset mode of operation). Refer to
“Operating Messages” on page 10-1 for an explanation of the
display codes.

Figure 8.4

Step/Direction Controller Connection Diagram

Intro

TB1

Phase R 1

Phase S 2

Phase T 3

Motor Gnd 4

J2

Motor
Encoder

J1

14 STEP+

15 STEP-

16 DIR+

Close to ENABLE Drive

Close to RESET Fault

17 DIR-

Close to Turn ON

21 FAULT

26 +24V

32 INPUT1

Step/Dir

Generator

20 ENABLE

Note 1. Refer to Figure 6.30 and 6.31 for additional details on the Control Interface Cable.

J4

DRIVE

TB1

2 RCV

3 XMT

5 COM

L1

L2/N

Gnd

XMT

RCV

COM

L1

L2/N

Gnd

100-240 VAC

50/60 Hz

Three Phase

Power Source

L3

or

100-240 VAC

50/60 Hz

Single Phase

Power Source

TB1

RESET

Advertising