Publication 1398-5.0 – October 1998

8-20

Application and Configuration Examples

14. Choose the

Drive

P

arameters

command icon from the Drive

window and then select the

Follower

tab.

15. Enter an appropriate

G

ear Ratio

as the Follower Input. The

default Gear Ratio is 1:1 (motor encoder pulses:master pulses). If
a Gear Ratio of 3:1 is entered, the motor is moved 3 encoder
pulses for every incoming step pulse.

16. Choose

Close

to exit the Drive Parameters window.

17. Select the

I/O

C

onfiguration

command icon from the Drive Win-

dow.

18. Select an appropriate digital input from the pull-down lists avail-

able as Digital Input Assignments in the I/O Configuration win-
dow.
For example:

Follower Enable

as Input 1

Not Assigned

as Inputs 2 through 4.

Not Assigned

as Outputs 1 through 4.

19. Choose

Close

to exit the I/O Configuration window.

Tuning

1. Choose the

Tuning

command icon from the Drive window.

2. Select

A

utoTune

from the Tuning mode group.

3. Select the appropriate values for the following Auto Tune com-

mands:

Distance

and

Step Current

.

4. Select the appropriate entry for the Motor Direction:

BiDirectional

,

Forward Only

or

Reverse Only

.

Note: Do not attempt to Auto Tune systems that have gravitational
effects. The ULTRA 200 Series will not hold initial position.