Interfaces

6-35

Even, odd, and no parity generation/checking are supported. No
parity is the factory default setting.

The maximum number of ULTRA 200 Series drives allowable on
an RS-485 bus is 32.

The maximum length of an RS-232 cable is 15 meters (50 feet).

The maximum length of an RS-485 cable is 1220 meters (4000

feet) with 0.20 mm

2

(24 AWG) wire.

Allen-Bradley cables are available in various lengths for connecting to
the serial port of an ULTRA 200 Series drive and a control unit, such
as a PC. “Options and Accessories” on page A-1 lists the cables, and
the male and female connectors for the cables.

The following table lists the pin-outs for J4 and J5.

Note: The shell of the connector is grounded to the chassis for shield
termination.

Table 6.24:

J4 and J5 – Serial Port Connector Pin-Outs

Signal Pin

Number

Description

Internal

Connections

RCV (+)
RCV (-)

J4 - 1 (+)
J4 - 7 (-)

RS-485 differential receiver input (to drive)

J5 - 1 (+)
J5 - 7 (-)

XMT (+)
XMT (-)

J4 - 4 (+)
J4 - 8 (-)

RS-485 differential transmitter output (from drive)

J5 - 4 (+)
J5 - 8 (-)

COM

J4 - 5

Common serial port interface

J5 - 5

J4 - 6

Reserved

a

J5 - 6

RCV

J4 - 2

RS-232 receiver input (to drive)

J5 - 2

XMT

J4 - 3

RS-232 transmitter output (from drive)

J5 - 3

J4 - 9

Reserved

1

J5 - 9

a. Do not connect any device to J4-6, J5-6, J4-9 or J5-9, except an Allen-Bradley TouchPad.