Publication 1398-5.0 – October 1998

Application and Configuration Examples

8-37

15. Enter the following values for Index 0.

16. Choose

Close

to exit the Drive Parameters window.

17. Select

I/O

C

onfiguration

command icon from the Drive Window.

18. Select an appropriate digital input from the pull-down lists avail-

able as Digital Input Assignments in the I/O Configuration win-
dow.
For example:

Start Index

as Input 1

Registration Sensor

as Input 2.

Not Assigned

as Inputs 3 and 4.

Not Assigned

as Outputs 1 through 4.

19. Choose

Close

to exit the I/O Configuration window.

Tuning

1. Choose the

Tuning

command icon from the Drive window.

2. Select

A

utoTune

from the Tuning mode group.

3. Select the appropriate values for the following Auto Tune com-

mands:

Distance

and

Step Current

.

4. Select the appropriate entry for the Motor Direction:

BiDirectional

,

Forward Only

or

Reverse Only

.

Note: The Registration Distance must be longer than the Deceleration
Distance or the move will not be registered.

Single Move Settings

Batched Move Settings

Registration

as Mode

Registration

as Mode

8000

as Distance

8000

as Distance

8000

as Registration Distance

1

as the Batch Count

3

as the Batch Count

0

as Dwell

1000

as Dwell

Appropriate values for Accelera-
tion and Deceleration

Appropriate values for Accelera-
tion and Deceleration

Note: Do not attempt to Auto Tune systems that have gravitational
effects. The ULTRA 200 Series will not hold initial position.