9. If the message box appears that a motor must be selected, select

OK

. The Drive Set Up window is displayed with Motor Model

selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor
displayed in the Motor Model box was previously selected.

10. Select or verify the correct motor model number from the drop

down Motor Model list.

11. If a message advises that the drive must be reset, choose

Yes

.

12. Select the Operation Mode parameters for the drive:

13. Choose

Close

to exit the Drive Set Up window.

14. Choose the

Drive

P

arameters

icon from the Drive window and

then select the

Analog

tab.

15. Enter appropriate S

cale

and O

ffset

values for the input.

Tuning

1. Choose the

Tuning

command icon from the Drive window. The

drive must be configured in Velocity mode for tuning to be effec-
tive.

2. Select

A

utoTune

from the Tuning mode group.

3. Select the appropriate values for the following Auto Tune com-

mands:

Distance

and

• Step Current

4. Select the appropriate entry for the Motor Direction:

BiDirectional

Forward Only

or

Reverse Only

Velocity Mode Settings

Torque Mode Settings

A

nalog Velocity Input

as the

Operation Mode

Analog Torque

I

nput

as the

Operation Mode

Note: Do not attempt to Tune a drive with the Command mode set for
Analog Torque Input. If the drive is set to Torque mode, continue with
the Operation section below.

Note: Do not attempt to Auto Tune systems that have gravitational
effects. The ULTRA 200 Series will not hold initial position.