Analog outputs, Analog 1 and analog 2 output circuits, Analog outputs: analog 1 and analog 2 – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 80

Advertising
background image

Publication 1398-5.0 – October 1998

6-16

Interfaces

Analog Outputs

Two selectable outputs are available for monitoring by the user:
ANALOG 1 (J1-30) and ANALOG 2 (J1-31). A 12 bit digital to
analog converter (DAC) generates ANALOG 1. ANALOG 2 is a
filtered PWM signal with 8 bit resolution and a carrier frequency of
32.8 kHz. Both outputs are scaled to a range of -10 to +10 Volts.

Figure 6.19

ANALOG 1 and ANALOG 2 Output Circuits

Intro

Drive

J1

-5 Volts

10K

100

-

+

20K

ANALOG
OUTPUT

!

Intro

ATTENTION: The user may need to provide an external
circuit to delay output of the analog signal when the signal
is used to perform an operation. After reset both analog
outputs may be in an indeterminate state for a short period
before they stabilize at the setting stored in memory. Failure
to observe this precaution could result in severe bodily
injury.

Table 6.15:

Analog Outputs: ANALOG 1 and ANALOG 2

Analog Output

Pin

Number

Description

Internal

Connections

ANALOG 1

J1-30

Selectable analog output with 12 bit resolution. Dis-
plays the selected firmware variable along with
selectable scale and offset (refer to the
ULTRA Master – I/O Configuration section).

A1

ANALOG 2

J1-31

Selectable analog output with 8 bit resolution. Dis-
plays the selected firmware variable along with
selectable scale and offset (refer to the
ULTRA Master – I/O Configuration section).

A2

ACOM

J1-28

Analog Common (return).

COM

Advertising