Publication 1398-5.0 – October 1998

7-12

Power Connections

If the application requires a higher continuous power dissipation, the
ULTRA 200 Series provides easy access to an external shunt
connection. Connecting an external resistor requires disabling of the
internal shunt resistor. Figure 7.4 depicts the use of one or more shunt
resistors to provide 1X, 4X or 9X resistance (200 Watts to 2.4 kWatts).

!

Intro

ATTENTION: Do not tin (solder) the exposed leads on
cables. Solder contracts over time and may loosen the
connection.

Table 7.8:

TB2 – Shunt Regulator Terminals

Terminal

Description

TB2-1

Positive DC bus

TB2-2

Internal shunt regulator resistor

TB2-3

Shunt regulator transistor collector

NOTE:Torque all terminal connections to 11.0 lb-in.

Table 7.9:

Internal Shunt Power Ratings for Drive Models

Drive Model

1398-DDM-

010,

1398-DDM-

010X

1398-DDM-

020,

1398-DDM-

020X

1398-DDM-

030,

1398-DDM-

030X

1398-DDM-

075,

1398-DDM-

075X

1398-DDM-

150,

1398-DDM-

150X

Continuous Shunt
Power (Watts)

50

50

50

50

180

Peak Shunt
Power (kWatts)

4.5

4.5

4.5

10.0

19.0

Table 7.10:

Maximum External Shunt Power Ratings for Drive Models

Drive Model

1398-DDM-

010,

1398-DDM-

010X

1398-DDM-

020,

1398-DDM-

020X

1398-DDM-

030,

1398-DDM-

030X

1398-DDM-

075,

1398-DDM-

075X

1398-DDM-

150,

1398-DDM-

150X

Continuous Shunt
Power (kWatts)

2.4

2.4

2.4

4.0

8.0

Peak Shunt
Power (kWatts)

6.0

6.0

6.0

10.0

19.0