Output interface circuit examples, Drive output connected to an opto-isolator, Transistor output specifications – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 75

Advertising
background image

Publication 1398-5.0 – October 1998

Interfaces

6-11

Output Interface Circuit Examples

Current Limit

An active state indicates the torque current is limited.

Up To Speed

An active state indicates the velocity loop AT SPEED signal is active. The at
speed level is a selectable setting.

Drive Enabled

An active state indicates the ENABLE signal is active and no fault is detected.

Bus Charged

An active state indicates the DC bus is energized.

Disabling Fault

An active state indicates a fault disabled the drive.

In Motion

An active state indicates the indexing sequence is in the motion portion.

In Dwell

An active state indicates the indexing sequence is in the dwell portion.

Sequence Complete

An active state indicates all batches of the indexing sequence are finished.

Registered

An active state indicates the indexing move has been adjusted after sensing
the registration sensor.

At Home

An active state indicates the drive is at the home position.

Axis Homed

An active state indicates the drive has been homed.

Table 6.10:

Transistor Output Specifications

Parameter

Description

Minimum

Maximum

ON state Voltage

Voltage difference between the +24 VDC
supply and the output when the transistor is
ON.

0 VDC

1.5 VDC

ON state current

Current flow when the transistor is ON.

0 mA

50 mA

OFF state Voltage

Voltage difference between the +24 VDC
supply and the output when the transistor is
OFF.

0 Volts

50 Volts

OFF state current

Leakage current from the output when the
transistor is OFF.

-0.1 mA

0.1 mA

Table 6.9:

OUTPUT1, OUTPUT2, OUTPUT3 and OUTPUT4 Functions

(continued)

Function

Description

Figure 6.10

Drive Output Connected to an Opto-Isolator

Intro

Drive

J1

+24VDC

Pin 13

Pin 6

24VCOM

1K

Advertising