Y-series motors to ultra 200 series drive, Y-series motor – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 241

Advertising
background image

Publication 1398-5.0 – October 1998

Cable Diagrams, Schematics and Examples

B-29

Figure B.29

Y-Series Motors to ULTRA 200 Series Drive
using P2 Terminal Strip

Intro

Notes:

This wiring method provides the option to run cables through a restrictive bulkhead or enclosure.

Cable 9101-1373-XXX has a connector on the motor end only. The cable connector is molded and
potted to the cable and may not be disassembled.

Adaptor Kits 9101-1391 and 9101-1392 include a 3 foot cable, 50-pin (9101-1391) or 25-pin screw
(9101-1392) terminal strip and mounting bracket. The cables have a 50 or 25-pin Mini D ribbon
connector at the drive end and a 50 or 25-pin D connector at the terminal strip end.

Motor Power Cables - Use ULTRA Series cable, 9101-1385-XXX, for applications requiring the
CE mark. The shield on the motor power cable must be properly grounded at both ends.

Y-Series Motors have 1 meter (39 inch) cables attached.

9101-1385-XXX

Clamp exposed

to the chassis

Y-Series Motor

P2

ground terminal

motor cable shield

Screw Terminal Strip

Enclosure/Cabinet

P1

9101-1391

To

Control

Interface

9101-1392

Screw Terminal Strip

Motor Power connectors

Encoder Connectors

9101-1373-XXX

Pigtail cable to
machine chassis ground

CPC connectors

Advertising