Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 93

Advertising
background image

Publication 1398-5.0 – October 1998

Interfaces

6-29

HALL A

J2-13

Hall Effect A sensor logic level input. Internally pulled up to +5VDC
through a 1 kOhm resistor.

The input signal interfaces to both a differential and single-ended
Hall effect sensor, using either a TTL level signal or open collector
signal. A differential output connects only the (+) output to the
drive.

Software determines when the hall effect sensors are in an illegal
state.

HALL B

J2-14

Hall Effect B sensor logic level input. Internally pulled up to +5VDC
through a 1 kOhm resistor.

The input signal interfaces to both a differential and single-ended
Hall effect sensor, using either a TTL level signal or open collector
signal. A differential output connects only the (+) output to the
drive.

Software determines when the hall effect sensors are in an illegal
state.

HALL C

J2-15

Hall Effect C sensor logic level input. Internally pulled up to +5VDC
through a 1 kOhm resistor.

The input signal interfaces to both a differential and single-ended
Hall effect sensor, using either a TTL level signal or open collector
signal. A differential output connects only the (+) output to the
drive.

Software determines when the hall effect sensors are in an illegal
state.

ABS

J2-16

Absolute Position used on Allen-Bradley motors for commutation.

J2-17
J2-18

Reserved.

TS (+)
TS(-)

J2-19
J2-20

Thermal Switch (+) and Thermal Switch (-) are thermostat inputs,
with an open condition indicating a motor overtemperature fault.

Table 6.22:

J2- Motor Encoder Connector Pin-Outs

(continued)

Motor Encoder

Pin Number

Description

Advertising