Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 131

Advertising
background image

Publication 1398-5.0 – October 1998

Application and Configuration Examples

8-7

3. Connect a Power cable from the motor to TB1 (terminals R, S, T

and

) on the drive.

4. Connect a jumper wire with a toggle switch between the follow-

ing pins:

• J1-20 (ENABLE) and J1-26 (I/O PWR)

• J1-32 (INPUT1) and J1-26 (I/O PWR)

• J1-33 (INPUT2) and J1-26 (I/O PWR)

• J1-34 (INPUT3) and J1-26 (I/O PWR)

• Connect a switch between J1-21 (FAULT RESET) and J1-26

(I/O PWR).

These connections provide manual control for enabling or disabling
the drive and resetting faults. The figure below shows the jumper,
including normally open toggle switches.

5. Connect the drive to a 100/240 VAC, 50/60 Hz power source

appropriate to the drive:

• Single Phase: 1398-DDM-010, 1398-DDM-010X,

1398-DDM-020, 1398-DDM-020X, 1398-DDM-030,
1398-DDM-030X, 1398-DDM-075 or 1398-DDM-075X

• Three Phase: 1398-DDM-075, 1398-DDM-075X,

1398-DDM-150 or 1398-DDM-150X

Advertising