Publication 1398-5.0 – October 1998

B-28

Cable Diagrams, Schematics and Examples

Figure B.28

Y-Series Motors to ULTRA 200 Series Drive

Intro

Notes:

This wiring method should be used to run cables through a bulkhead or enclosure without
removing the connectors.

Cable 9101-1375-XXX has connectors on both ends. The connectors are molded and potted
to the cable and may not be disassembled.

Adaptor Kit 9101-1391 includes the 3 foot cable, screw terminal strip and mounting bracket.
The cable has a 50-pin Mini D ribbon connector at the drive end and a 50-pin D connector at
the terminal strip end.

Motor Power Cables - Use ULTRA Series cable, 9101-1385-XXX, for applications requiring
the CE mark. The shield on the motor power cable must be properly grounded at both ends.

9101-1385-XXX

Clamp exposed

to the chassis

Y-Series Motor

P2

9101-1375-XXX

ground terminal

motor cable shield

Screw Terminal Strip

Enclosure/Cabinet

P1

9101-1391

To

Control

Interface

Motor Power connectors

Encoder Connectors

Pigtail cable to
machine chassis ground

CPC connectors