C-16

TouchPad Instructions

Table C.16:

Analog Output Parameter List for TouchPad

Display

Parameter

I Cmd

Current Command

I Avg

Average Current Command

IPeak+

Positive Current Peak

IPeak-

Negative Current Peak

ILimit+

Positive Current Limit

ILimit-

Negative Current Limit

VelMtr

Motor Velocity

VelCmd

Velocity Command

VelErr

Velocity Error

PosMtr

Motor Position

PosCmd

Position Command Slewed

PosErr

Position Error

PosEPk+

Positive Position Peak Error

PosEPk-

Negative Position Peak Error

PosMstr

Master Position

Table C.17:

Drive Status List for TouchPad

Display

Parameter

DrvEnab

Drive Enabled

DrvRdy

Drive Ready

+24 Fuse

+24 VDC Fuse blown

5v Fuse

+5 VDC Fuse blown

EncFuse

Encoder Power Fuse blown

MtrOvT

Motor Thermostat Overtemperature

IPMFalt

IPM Fault (Overtemperature/Overcurrent/Short Circuit)

IMLinBk

Channel IM Line Break

BMLinBk

Channel BM Line Break

AMLinBk

Channel AM Line Break

BusOvV

Bus Undervoltage

BusUndV

Bus Overvoltage

IlglHal

Illegal Hall State

SubIntr

Unused Interrupt - sub processor

MainInt

Unused Interrupt - main processor

ExsAvgI

Excessive Average Current

OvSpeed

Motor Overspeed

ExsFErr

Excessive Following Error

MtrEnc

Motor Encoder State Error

MstrEnc

Auxiliary Encoder State Error

MtrThrm

Motor Thermal Protection

IPMThrm

IPM Thermal Protection

EnNoMtr

No Motor Selected while enabling drive

MtrType

Motor Selection not in Table