Publication 1398-5.0 – October 1998

Application and Configuration Examples

8-9

• If the settings are different, correct the Port – Settings to allow

communications with the drive.

Factory default communications Port – Settings for the drive
are:

– Baud Rate:

9600

– Data Bits:

8

– Parity:

None

– Stop Bits:

1

– Serial Port:

COM1

Refer to the section “RS-232 Communication Test” on page 11-11
for troubleshooting instructions.

6. Select

Read Drive

P

arameters

from the Communications menu.

7. Verify the Drive Name and Address are correct for the drive that

is being addressed.

8. Choose

OK

to load the drive parameters.

9. If the message box appears that a motor must be selected, select

OK. The Drive Setup window is displayed with Motor Model
selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor
displayed in the Motor Model box was previously selected.

10. Select or verify the correct motor model number from the drop

down Motor Model list.

11. If a message advises that the drive must be reset, choose

Yes

,

12. Select the Operation Mode parameter for the drive:

13. Choose

Close

from the Drive Setup window.

14. Choose the

Drive

P

arameters

command icon from the Drive

window and then select the

Preset

tab.

15. Enter the appropriate parameters for the Command mode in

which the drive will operate:

Up to eight presets (0-7) may be programmed.

Note: A motor must be selected for the parameters to load.

Velocity Mode Settings

Torque Mode Settings

Preset

V

elocities

as the Opera-

tion Mode

Preset

T

orques

as the Opera-

tion Mode

Velocity Mode Settings

Torque Mode Settings

Enter the appropriate velocity
value for each speed required

Enter the appropriate current value
for each torque required