Connection diagram, Configuration, Preset controller connection diagram – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 132: Connection diagram configuration

Advertising
background image

Publication 1398-5.0 – October 1998

8-8

Application and Configuration Examples

Connection Diagram

Configuration

Carefully check all connections before entering these parameters.

1. Switch the AC Power to ON and verify:

• green DC BUS LED is ON

• display shows an operational status: A, F or P (Analog, Fol-

lower or Preset mode of operation). Refer to “Operating Mes-
sages” on page 10-1 f
or an explanation of the display codes.

2. Start ULTRA Master on the PC.

3. Choose

Cancel

from the Drive Select dialog box.

4. Select

P

C Set Up

from the Communications menu in

ULTRA Master to display the personal computer’s communica-
tion settings

5. Verify the communications port settings of the PC match those of

the drive.

• If the settings are correct, select

OK

in the Port – Settings dia-

log box.

Figure 8.2

Preset Controller Connection Diagram

Intro

J1

26 +24V

20 ENABLE

21 FAULT

32 INPUT1

33 INPUT2

Close to ENABLE Drive

Close to RESET Fault

34 INPUT3

Close to Turn ON

Close to Turn ON

Close to Turn ON

DRIVE

TB1

L1

L2/N

Gnd

L1

L2/N

Gnd

100-240 VAC

50/60 Hz

Three Phase

Power Source

L3

or

100-240 VAC

50/50 Hz

Single Phase

Power Source

TB1

J4

2 RCV

3 XMT

5 COM

XMT

RCV

COM

RESET

TB1

Phase R 1

Phase S 2

Phase T 3

Motor Gnd 4

J2

Motor
Encoder