6-32

Interfaces

Table 6.23:

J3 – Auxiliary Connector Pin-Outs

Motor Encoder

Pin Number

Description

Internal

Connections

+ 5V

J3-1
J3-3

Encoder +5 VDC @ 250 mA power source
for auxiliary encoder electronics.

The output is fused internally by a 1 Amp fast
acting fuse (F2).

Refer to “5 Volt Power Supply Specifications”
on page 6-4.

J1-1, J1-3
J3-1, J3-3

ECOM

J3-2
J3-4

Encoder common. Signal reference for the
auxiliary encoder.

Refer to “5 Volt Power Supply Specifications”
on page 6-4.

J1-2, J1-4
J3-2, J3-4

+ 24V

J3-5
J3-26

Isolated + 24 VDC @ 500 mA power source
for external I/O connection.

This output is fused internally by a 1 Amp
fast acting fuse (F1).

Refer to “24 Volt Power Supply Specifica-
tions” on page 6-3.

J1-5
J1-26

24VCOM

J3-6
J3-13

Isolated 24 Volt common.

Refer to “24 Volt Power Supply Specifica-
tions” on page 6-3.

J1-6
J1-13

AOUT (+)
AOUT (-)

J3-7 (+)
J3-8 (-)

Motor Output Channels A(+) and A(-). Differ-
ential TTL levels from line driver.

Refer to “Motor Encoder Output Signal” on
page 6-18 and
Figure 6.20.

J1-7 (+)
J1-8 (-)

BOUT (+)
BOUT (-)

J3-9 (+)
J3-10 (-)

Motor Output Channels B(+) and B(-). Differ-
ential TTL levels from line driver.

Refer to “Motor Encoder Output Signal” on
page 6-18 and
Figure 6.20.

J1-9 (+)
J1-10 (-)

IOUT (+)
IOUT (-)

J3-11 (+)
J3-12 (-)

Motor Output Channels I(+) and I(-). Differen-
tial TTL levels from line driver.)

Refer to “Motor Encoder Output Signal” on
page 6-18 and
Figure 6.20.

J1-11 (+)
J1-12 (-)

AX+ and AX-,
or
Step+ and Step-,
or
CW (Step Up+) and
CW (Step Up-)

J3-14 (+)
J3-15 (-)

Auxiliary Channel A(+) and A(-). Differential,
quadrature, or TTL level encoder input. The
signals are selectable as AX+ and AX-, or
Step+ and Step-, or CW (Step Up+) and
CW (Step Up-).

For encoder information refer to “Quadrature
Interface Specifications” on page 6-20 and

Figure 6.23, 6.24, 6.25, 6.26, 6.27, 6.28 and
6.29.

For stepper information refer to“Step/Direc-
tion and CW/CCW (Step Up/Step Down)
Interface Specifications” on page 6-24 and

Figure 6.30, 6.31, 6.32 and 6.33.

J1-14 (+)
J1-15 (-)