Application and Configuration Examples

8-23

Connection Diagram

Configuration

Carefully check all connections before entering these parameters.

1. Switch the AC Power to ON and verify:

• green DC BUS LED is ON

• display shows an operational status: A, F or P (Analog, Fol-

lower or Preset mode of operation). Refer to “Operating Mes-
sages” on page 10-1 f
or an explanation of the display codes.

2. Start ULTRA Master on the PC.

3. Choose

Cancel

from the Drive Select dialog box.

4. Select

P

C Set Up

from the Communications menu in

ULTRA Master to display the personal computer’s communica-
tion settings.

Figure 8.5

Step Up/Step Down Controller Connection Diagram

Intro

J1

14 CW+

15 CW-

16 CCW+

Close to ENABLE Drive

Close to RESET Fault

17 CCW-

Close to Turn ON

21 FAULT

26 +24V

32 INPUT1

20 ENABLE

Step

Indexer

Note 1. Refer to Figure 6.32 and 6.33 for additional details on the Control Interface Cable.

J4

DRIVE

TB1

2 RCV

3 XMT

5 COM

L1

L2/N

Gnd

XMT

RCV

COM

L1

L2/N

Gnd

100-240 VAC

50/50 Hz

Three Phase

Power Source

L3

or

100-240 VAC

50/50 Hz

Single Phase

Power Source

TB1

RESET

TB1

Phase R 1

Phase S 2

Phase T 3

Motor Gnd 4

J2

Motor
Encoder