J3 – Auxiliary Port

J3 is a 26 pin female mini-D ribbon connector (AMP 2-178238-4). It
duplicates the first 26 pins of J1, the Controller connector, which are
discussed in detail beginning on page 6-1. Contact between the
connector shell and the grounded chassis provides shield termination.

Allen-Bradley cables are available in various lengths for connecting
between J3 and an auxiliary unit. “Options and Accessories” on
page A-1
lists the cables that are available.

Pin Signal

Description

Pin Signal

Description

1 +5VDC

Encoder +5V
DC

14 AX+

Auxiliary
Channel A+

2 ECOM

Encoder
Common

15 AX-

Auxiliary
Channel A-

3 +5VDC

Encoder +5V
DC

16 BX+

Auxiliary
Channel B+

4 ECOM

Encoder
Common

17 BX-

Auxiliary
Channel B-

5 +24VDC

Isolated +24
VDC

18 IX+

Auxiliary
Channel I+

6 24VCOM Isolated 24V

Common

19 IX-

Auxiliary
Channel I-

7 AOUT+

Motor Output
Channel A+

20 ENABLE

ENABLE

8 AOUT-

Motor Output
Channel A-

21 RESET

FAULT
RESET

9 BOUT+

Motor Output
Channel B+

22 COMMAND+ Analog

Command+

10 BOUT-

Motor Output
Channel B-

23 COMMAND-

Analog
Command-

11 IOUT+

Motor Output
Channel I+

24 READY+

READY+

12 IOUT-

Motor Output
Channel I-

25 READY-

READY-

13 24VCOM Isolated 24V

Common

26 +24VDC

+Isolated +24
VDC

pin 13

pin 14

pin 26

pin 1