Chapter 7

Power Connections

Chapter 7

TB1 – DC Bus and AC Power

Refer to Figure 5.4 on page 5-11 for power wiring connection
diagrams for the drives.

Description

Identifier

1398-DDM-010 and

1398-DDM-010X

1398-DDM-020 and

1398-DDM-020X

1398-DDM-030 and

1398-DDM-030X

Terminal

1398-DDM-075 and

1398-DDM-075X

1398-DDM-150 and

1398-DDM-150X

Identifier

Description

R phase power
to motor

R

1

R

R phase power
to motor

S phase power
to motor

S

2

S

S phase power
to motor

T phase power
to motor

T

3

T

T phase power
to motor

Motor case
ground

4

Motor case
ground

DC Bus
+ voltage

DC BUS +

5

DC BUS + DC Bus

+ voltage

DC Bus
- voltage

DC BUS -

6

DC BUS -

DC Bus
- voltage

100/240 VAC
input power

L1
(Line 1)

7

L1 (Line 1) 100/240 VAC

input power

100/240 VAC
input power

L2
(Line 2)/
N
(Neutral)

8

L2
(Line 2)/
N
(Neutral)

100/240 VAC
neutral

Safety (earth)
ground

9

L3 (Line 3) 100/240 VAC

input power for
three phase

1

Auxiliary 100/
240 VAC input
power

L1 AUX

10

Safety (earth)
ground

Auxiliary 100/
240 VAC input
power

L2/N AUX

11

L1 AUX

Auxiliary 100/
240 VAC input
power

1
CAUTION: When operating
1398-DDM-075 with a sin-
gle phase power input the
current limits must be set
correctly.

12

L2 AUX

Auxiliary 100/
240 VAC
neutral for
three phase

Advertising