Digital outputs, Dedicated relay outputs, Selectable transistor outputs – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 73: Ready and brake circuits, Ready output specifications

Advertising
background image

Publication 1398-5.0 – October 1998

Interfaces

6-9

Digital Outputs

Two types of discrete output circuits are available on the J1 connector:

Dedicated relay outputs

Selectable transistor based outputs

Both types support 24 VDC logic interfaces:

Dedicated Relay Outputs

BRAKE and DRIVE READY. Each output is a normally open relay.
The brake contacts are rated for 1 Amp at 50 Volts. The Drive Ready
contacts are rated for 100 mA at 50 Volts.

If an option, such as 90V brake, requires more power, a user provided
relay may be driven by these outputs up to the specified levels.

Selectable Transistor Outputs

OUTPUT 1, OUTPUT 2, OUTPUT 3, and OUTPUT 4 are 24 VDC,
optically isolated, active high, current sourcing, single ended
transistor output channels. Each channel sources a maximum of 50
mA.

Ready and Brake Circuits

The specifications for these outputs are as follows:

Figure 6.8

READY and BRAKE Circuits

Intro

J1

Drive

+

-

Normally

Open

Relay

Table 6.6:

READY Output Specifications

Parameter

Description

Maximum

ON state resistance

Internal resistance between J1-24 (+) and J1-25 (-) when
the contacts are closed.

1 Ohm

ON state current

Current flow through the relay when contacts are closed.

100 mA

OFF state current

Leakage current from either output when the relay contacts
are open.

0.01 mA

OFF state Voltage

Voltage difference between the outputs with open relay
contacts.

50 Volts

Advertising