Storing the unit – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 49

Advertising
background image

Publication 1398-5.0 – October 1998

Unpacking, Inspecting and Storing

4-7

24. Choose

Drive

E

nable

and verify the motor shaft has holding

torque. (i.e., The shaft cannot be moved or moves with resis-
tance.)

25. Open the connection between J1-26 and J1-20 to disable the drive.

26. Choose

Close

from the Control Panel window.

A drive completing these steps is functional. If the ULTRA 200 Series
drive did not pass the steps above, refer to “Troubleshooting” on
page 11-6
.

Storing the Unit

Return the ULTRA 200 Series drive to its shipping carton using the
original packing materials to enclose the unit.

Store the drive in a clean, dry place that will not exceed the following
ranges:

Humidity: 5% to 95%, non-condensing

Storage temperature: -40

°

to 70

°

C (-40

°

to 158

°

F)

Note: For information on testing digital and analog signals, refer to
“Testing Digital Outputs” on page 11-12, “Testing Digital Inputs” on
page 11-14, “Testing Analog Outputs” on page 11-14
and “Testing Pos-
itive and Negative Current Limits” on page 11-15