Storing the unit – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual
Page 49

Publication 1398-5.0 – October 1998
Unpacking, Inspecting and Storing
4-7
24. Choose
Drive
E
nable
and verify the motor shaft has holding
torque. (i.e., The shaft cannot be moved or moves with resis-
tance.)
25. Open the connection between J1-26 and J1-20 to disable the drive.
26. Choose
Close
from the Control Panel window.
A drive completing these steps is functional. If the ULTRA 200 Series
drive did not pass the steps above, refer to “Troubleshooting” on
page 11-6.
Storing the Unit
Return the ULTRA 200 Series drive to its shipping carton using the
original packing materials to enclose the unit.
Store the drive in a clean, dry place that will not exceed the following
ranges:
●
Humidity: 5% to 95%, non-condensing
●
Storage temperature: -40
°
to 70
°
C (-40
°
to 158
°
F)
Note: For information on testing digital and analog signals, refer to
“Testing Digital Outputs” on page 11-12, “Testing Digital Inputs” on
page 11-14, “Testing Analog Outputs” on page 11-14 and “Testing Pos-
itive and Negative Current Limits” on page 11-15