B. Brake Enable box, then measure the resistance between J1-49

and J1-50.

(a) If the box is checked, the resistance should read

approximately 1Ohm.

(b) If the box is not checked, the resistance should be very

high (> 1 MOhm).

A load is necessary to test the transistor outputs listed below.
A 1 kOhm resistor may be connected from the transistor
output (J1-42, J1-43, J1-44 or J1-45) to the 24 VCOM (J1-6).

C. Digital Output 1, then measure the voltage between J1-42 and

J1-13.

(a) If the box is checked, the voltmeter should read

approximately +24 VDC.

(b) If the box is not checked, the voltmeter should read

approximately 0 VDC.

D. Digital Output 2, then measure the voltage between J1-43 and

J1-13.

(a) If the box is checked, the voltmeter should read

approximately +24 VDC.

(b) If the box is not checked, the voltmeter should read

approximately 0 VDC.

E. Digital Output 3, then measure the voltage between J1-44 and

J1-13.

(a) If the box is checked, the voltmeter should read

approximately +24 VDC.

(b) If the box is not checked, the voltmeter should read

approximately 0 VDC.

F. Digital Output 4, then measure the voltage between J1-45 and

J1-13.

(a) If the box is checked, the voltmeter should read

approximately +24 VDC.

(b) If the box is not checked, the voltmeter should read

approximately 0 VDC.

4. After the test has been completed you may select Close to exit

Output Diagnostics window.

If you determine that a digital output is defective, return the unit for
repair.