Power Connections

7-7

AC Power Cabling

The ULTRA 200 Series drives require 100 to 240 VAC rms power
with an input frequency of 47 - 63 Hz. The 1398-DDM-010,
1398-DDM-010X, 1398-DDM-020, 1398-DDM-020X, 1398-DDM-
030 and 1398-DDM-030X require single phase input power. The
1398-DDM-075 and 1398-DDM-075X may use either single or three-
phase input power, but the 1398-DDM-150 and 1398-DDM-150X
require three-phase input power. “ULTRA 200 Series Power Ratings”
on page G-5 l
ists the output power characteristics of the ULTRA 200
Series drives. The AC input supplies power to the motor and the drive
logic as the default factory setting. An auxiliary power source may
provide input power to the drive I/O independent of the motor power.
Alternatively, the drive may be powered by an external DC power
source.

Figure 7.3

Emergency Stop Contactor Wiring

Intro

Table 7.3:

TB1 – DC Bus Terminals

Signal

Description

Terminal

DC Bus +

Positive DC Bus voltage signal

TB1-5

DC Bus -

Negative DC Bus voltage signal

TB1-6

NOTE: Torque all terminal connections to 1.25 Nm (11.0 lb-in).

R

S

T

Drive

R

S

T

Motor

GND

GND

Isolated terminal

Grounded terminal or stud

Unbraided shield

Enclosure wall

Overlapping

Contactor

Resistor

Resistor

Resistor