Digital i/o power, 24 volt i/o power, 5 volt i/o power – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 67: 24 volt power supply specifications

Advertising
background image

Publication 1398-5.0 – October 1998

Interfaces

6-3

Digital I/O Power

ULTRA 200 Series drives provide +24VDC and +5VDC to power
external devices within the following specifications.

24 Volt I/O Power

One isolated 24 Volt power supply is accessible from the connector:

The allowable load is <500 mA.

The pin-outs are:

This supply is intended for powering the digital I/O circuitry.

The 24 VCOM is a floating ground. It must be grounded during
installation to meet the European Low Voltage Directive (LVD).

The +24 Volt power supply is internally fused by F1, a 1 Amp, fast
acting fuse. Refer to “Fuse and Jumper Locations” on page 11-4, for
the location of F1.

5 Volt I/O Power

One +5 Volt power supply is accessible from the connector:

The allowable load is <250 mA.

The pin-outs are:

This supply is intended for powering an auxiliary encoder.

The +5 Volt power supply is internally fused by F2, a 1 Amp, fast
acting fuse. Refer to “Fuse and Jumper Locations” on page 11-4, for
the location of F2.

+24VDC

J1-5

J1-26

J3-5

J3-26

24VCOM

J1-6

J1-13

J3-6

J3-13

Note: If an external +24VDC power source will power the I/O, remove
jumpers P5 and P6. Refer to “Fuse and Jumper Locations” on page 11-4,
for the location of the jumpers.

Table 6.1:

24 Volt Power Supply Specifications

Parameter

Description

Minimum

Maximum

Output Voltage

(VDC)

Voltage difference between +24VDC and
24VCOM

21.6

26.4

Output Current

(mA)

Current flow

0

500

+5 VDC

J1-1

J1-3

J3-1

J3-3

ECOM

J1-2

J1-4

J3-2

J3-4

Advertising