Specifications

Bus Capacitance

(

µ

F)

1170

1950

2730

4290

7520

Peak Power Output

b

(kWatts @ 120 V

rms

)

(kWatts @ 240 V

rms

)

1.25

2.5

2.5

5

3.75

7.5

14, 1

20, 3

36

Continuous Power Output

2

(kWatts @ 120 V

rms

)

(kWatts @ 240 V

rms

)

0.6

1.0

1.2

2.0

1.8

3

3.5

7.5, 3

15, 3

a. Bus capacitance energy absorption is based on the following equations:

b. Power outputs are based on the following equation:

Table G.1:

ULTRA 200 Series Power Ratings

(continued)

1398-DDM-

010,

1398-DDM-

010X

1398-DDM-

020,

1398-DDM-

020X

1398-DDM-

030,

1398-DDM-

030X

1398-DDM-

075,

1398-DDM-

075X

1398-DDM-

150,

1398-DDM-

150X

ε

1
2

---C V

2

f

(

)

1
2

---C V

2

i

(

)

=

ε

1
2

---C 420

(

)

2

1
2

---C 325

(

)

2

=

1
2

---C

420

2

325

2

(

)

C 35387

(

)

=

if C

7520

µ

F

=

,

ε

266

=

Output Power (in Watts)

3
2

---

 

 

0.85

(

)

(input rms Volts)(output Amps)

=

Advertising